Hembrug DrillPress BoorKolom PillarDrill: verschil tussen versies
(→Safety Relay, Stop button) |
|||
Regel 8: | Regel 8: | ||
− | + | # Handle for up/down of the head. Clockwise for down; Counterclockwise for up. Do not forget to (un)tighten handle 9. | |
− | + | # Handle for the speed. | |
− | + | # Hole through which you can see the current speed. The lower number is for "speed I" the high number for 'speed 2" (they are exactly 2x apart). | |
− | + | # Speed switch;; 0 is off, 1 is low speed and 2 is twice as fast. | |
− | + | # The normal on/off switches; prevents the machine from switching on spontaneously after a power failure -and- enforce a current limit/emergency stop. | |
− | + | # Emergency button. Do not use as an on-off button ! | |
− | + | # Limiters for the travel | |
− | + | # Small scale; which you can adjust to see the travel in mm. | |
− | + | # Handle to lock vertical travel. | |
− | + | # Keyless drill chuck (taper not yet measures) | |
== Safety Relay, Stop button == | == Safety Relay, Stop button == |
Versie van 24 okt 2021 om 22:19
This equipment is safety category 4:
- In-person, instructions strongly advised but not mandatory.
- Reading, and following, the instructions on the Wiki is mandatory!
This equipment is Noise Category 2:
Can be used at all hours, but in moderation.
Be considerate; if you feel you need to wear ear protection,
then only use the tool between 07:00 and 19:00.
Page about the changes/setup of the Hembrug pillar dril.
- Handle for up/down of the head. Clockwise for down; Counterclockwise for up. Do not forget to (un)tighten handle 9.
- Handle for the speed.
- Hole through which you can see the current speed. The lower number is for "speed I" the high number for 'speed 2" (they are exactly 2x apart).
- Speed switch;; 0 is off, 1 is low speed and 2 is twice as fast.
- The normal on/off switches; prevents the machine from switching on spontaneously after a power failure -and- enforce a current limit/emergency stop.
- Emergency button. Do not use as an on-off button !
- Limiters for the travel
- Small scale; which you can adjust to see the travel in mm.
- Handle to lock vertical travel.
- Keyless drill chuck (taper not yet measures)
Safety Relay, Stop button
A safety relay was added; with a 4-6 amp current limiters along with an emergency stop button. Normal ground/earth wiring was added.
The current rotary switch does NOT allow for a switch-on block when in the wrong position. We need to find a replacement switch.
Motor