VK2000
Place holder for the VeKa Ovenbouw "Firing Control V-K2000" Ceramics oven controller. It is a rebadged Brentrup unit.
See VK2000-build for details on wiring, etc.
Concept
The unit has several programs; each has a certain ramp-up rate; a dwell/soak time; then a ramp-up to firing at some specific rate followed by a baking period at a certain temperature for a certain time. And it finishes with a cooldown.
Manual
Errors
Always first check the manual and follow the steps in order. F1: This error will occur when the temperature will not rise (fast enough) within a given timeframe. Be aware that it takes about 30 minutes after the oven has been switched on before it occurs. The F1 error can occur when the temperature fuse is broken. You can find it at the left side of the oven behind the panel. Unscrew it and check with a multimeter.