Gas Bottle Pressure Vessel Limit: verschil tussen versies
k (Gassenvooraad geupdated) |
|||
Regel 74: | Regel 74: | ||
| | | | ||
| 84.8 | | 84.8 | ||
+ | |} | ||
+ | |||
+ | = Per 01/04/2020 = | ||
+ | |||
+ | {| class="wikitable" | ||
+ | ! Aantal | ||
+ | ! Waterinhoud | ||
+ | ! Soort Gas | ||
+ | ! Totaal | ||
+ | |- | ||
+ | | 1 | ||
+ | | 26.2 | ||
+ | | Propaan | ||
+ | | 26.2 | ||
+ | |- | ||
+ | | 1 | ||
+ | | 10 | ||
+ | | Argon | ||
+ | | 10 | ||
+ | |- | ||
+ | | 1 | ||
+ | | 10 | ||
+ | | Argon/CO2 | ||
+ | | 10 | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2.2 | ||
+ | | Argon | ||
+ | | 2.2 | ||
+ | | Liggen in de laskast - van wie zijn deze? Kunnen wij ze :uberhaupt gebruiken? | ||
+ | |- | ||
+ | | 1 | ||
+ | | 2.2 | ||
+ | | Argon/CO2 | ||
+ | | 2.2 | ||
+ | | - " - " - | ||
+ | |- | ||
+ | | Totaal | ||
+ | | | ||
+ | | | ||
+ | | 50.6 | ||
|} | |} |
Versie van 1 apr 2020 om 00:10
Er zijn een aantal extra regels voor gasflessen. Dit om te voldoen aan de wet, regelgeving en de omgevingsvergunning.
De belangrijkste zijn
- Er mag nooit meer dan 125 Liter water equivalent volume aan gasflessen op de makerspace zijn. Elk volume telt - dus ook een LEGE fles.
- De gascylinders moeten ten alle tijden geborgd zijn - zodat ze niet om kunnen vallen (met uitzondering van de `dikke lage' butagas flessen voor het kacheltje die gemaakt zijn om zelfstanding te staan).
- De gascyclinders moeten dichtgedraaid zijn als er geen mensen actief mee werken.
De 125L regel is inclusief LEGE tanks.
Onderschat het belang van de 125 Liter regel niet - bij overtreding zijn de gevolgen groot en `direct'. De ambtenaar die de overtreding constateert heeft een buitengewoon groot mandaad om onmiddelijk en zeer definief `voor het zekere' op te treden; alle `eerlijk process' zaken komen pas achteraf aan bod - in vaak zeer lange, slepende processen.
The rules and regulation (and specifically - our permit) require the following:
- Gas cylinders must be kept mounted in their stand with a safety strapat all times.
- There should never be more than a total125L of ‘water equivalent’volume, aggregated across all bottles (full or empty) at the space.
- Cylinders must be closed when not use.
Do not underestimate the impact of the 125L rule. Violations tent to have almost disproportional consequences; and the inspector is authorised to act immediately and with virtually none of the normal fair-process law protection limits applying. These are all `postponed' and sorted ou later in very lengthy processes during which one is seriously hampered.
Per 01/04/2019
Aantal | Waterinhoud | Soort Gas | Totaal | |
---|---|---|---|---|
2 | 26.2 | Propaan | 52.4 | |
1 | 10 | Argon | 10 | |
1 | 10 | Argon/CO2 | 10 | |
1 | 5 | Argon/CO2 | 5 | als tijdelijke overbrugging tot de 10 liter vervangen is |
1 | 2.2 | Argon | 2.2 | |
1 | 2.2 | Argon/CO2 | 2.2 | |
1 | 3 | CO2 | 3 | |
Totaal | 84.8 |
Per 01/04/2020
Aantal | Waterinhoud | Soort Gas | Totaal | |
---|---|---|---|---|
1 | 26.2 | Propaan | 26.2 | |
1 | 10 | Argon | 10 | |
1 | 10 | Argon/CO2 | 10 | |
1 | 2.2 | Argon | 2.2 | Liggen in de laskast - van wie zijn deze? Kunnen wij ze :uberhaupt gebruiken? |
1 | 2.2 | Argon/CO2 | 2.2 | - " - " - |
Totaal | 50.6 |