Firing Control VK-200, Ve-Ka Ovenbouw

Firing Control VK-200, Ve-Ka OvenbouwFiring Control VK-200, Ve-Ka OvenbouwFiring Control VK-200, Ve-Ka Ovenbouw

Wiring

  1. N and single 220volt L via switch; black and blue
  2. 2x for the thermocouple - orange cable; white and brown
  3. 2x Normally open relays to switch a load contactor
  4. Earth wire

On a Harting HAN7Da connector.

RCD / Aardlekschakelaar

40A, 150mA?? residual current detector/aartlekschakelaar in de loop

kWh meter

Dit is een DTS353 -- https://www.rdlmeters.com/product/dts353/ met een Wat-uur puls uitgang. Deze is vermoedelijk low-voltage open collector. Plan is te beginnen met 5volt en een pull up weerstand.

Manual

Sensor

  • Nenniger GmbH, Berlin, Hochtemperatur S-Type Thermocouple
  • Special type of cable for this (orange)

Hitte Sensor

een FIT-NP5R dry-relay (NO, NC) sokkel met een FITH-23010 hitte sensor.

Manual hittemelder Manual Sokkel

Manuals as shipped

Actual manuals that were shipped with the unit (please keep)

Scan Manual hittemelder Scan Manual Sokkel

VK2000 Control signals

Our version has 2 relays; with an NO to the 'L'.

  1. Earth wire (yellow/green)
  2. Neutral wire (for the AC/DC) (blue)
  3. L wire (for AC/DC and as the feed of the relay outputs) (brown)
  4. Relay 1 out -- switching to L (black)
  5. Relay 2 out -- Switching to L (green)
  6. Purple wire - not connected
  7. Orange wire - white/brown - Pt

Manual

VK-20000 fire control manual

Wiring Oven side =

Ovenconn-schamatic.png

Harting style 6+1 connector carrying 3 phase power and relay control signal

  • 2 pins for Neutral and Switch (relay)
  • 3 pins for the 3 phases
  • E pin for Earth

Ovenconn-1.jpg Ovenconn-2.jpg Ovenconn-3.jpg

Ovenrelay-1.jpg Ovenrelay-2.jpg Ovenspec-1.jpg

todo

Probably needs a snubber

Risks

Inherent

  1. Heat runaway (CPU fault, contacts welded)
  2. Faulty thermocouple causing heat runaway / instability / cracking
  3. Contact with water/leak
  4. Material falling onto it / other people working too near / unclear that is hot

Operator driven

  1. Flammable material near
  2. Hot handles, etc
  3. Dust
  4. Unclear it is on / hot
  5. Opening while hot
  6. Bare wire touching
  7. Looking into it / infrared radiation

Measures

  1. Earth leak trip/detector (touching bare metal)
  2. Heat sensor above oven
  3. Heat fuse 1 (firing relay), heat fuse 2 (interlock)
  4. Emergency button
  5. VK2000 validates heat/cool & stops firing outside control range
  6. Check ACNode for current & firing
  7. Overcurrent protection
  8. No unknown/uncontrolled states on powerup / after powerlock
  9. Instructions
  10. Signage (eye, heat, ..)