+ | = Wiring = | ||
+ | |||
+ | * Mains | ||
+ | ** L -- Phase 220v, Brown | ||
+ | ** N -- Neutral, 220v, Blue | ||
+ | ** Earth - terminated, Yellow | ||
+ | ** Alert-signal, white -- not connected | ||
+ | ** Dry relay - galvanically separate from mains. | ||
+ | ** Black - common | ||
+ | ** Red - Normally open | ||
+ | ** Blue - Normally closed | ||
+ | |||
+ | [[Bestand:hitte-1.jpg|heat sensor - wiring]] | ||
+ | [[Bestand:hitte-2.jpg|heat sensor - wiring]] | ||
+ | [[Bestand:hitte-3.jpg|heat sensor - wiring]] | ||
+ | [[Bestand:hitte-4.jpg|heat sensor - location]] | ||
= VK2000 Control signals = | = VK2000 Control signals = |
Versie van 30 jan 2024 om 17:41
Inhoud
Wiring
- N and single 220volt L via switch; black and blue
- 2x for the thermocouple - orange cable; white and brown
- 2x Normally open relays to switch a load contactor
- Earth wire
On a Harting HAN7Da connector.
RCD / Aardlekschakelaar
40A, 500mA residual current detector/aartlekschakelaar in de loop. It sits in the path to the 4+1 IEC wall socket.
kWh meter
Dit is een DTS353 -- https://www.rdlmeters.com/product/dts353/ met een Wat-uur puls uitgang.
Deze is vermoedelijk low-voltage open collector. Plan is te beginnen met 3v3 volt en een 4.7 kΩ pull up resistor on the IO port of the node..
Sensor
- Nenniger GmbH, Berlin, Hochtemperatur S-Type Thermocouple
- Special type of cable for this (orange)
Hitte Sensor
een FIT-NP5R dry-relay (NO, NC) sokkel met een FITH-23010 hitte sensor.
Manuals as shipped
Actual manuals that were shipped with the unit (please keep)
Wiring
- Mains
- L -- Phase 220v, Brown
- N -- Neutral, 220v, Blue
- Earth - terminated, Yellow
- Alert-signal, white -- not connected
- Dry relay - galvanically separate from mains.
- Black - common
- Red - Normally open
- Blue - Normally closed
VK2000 Control signals
Our version has 2 relays; with an NO to the 'L'.
- Earth wire (yellow/green)
- Neutral wire (for the AC/DC) (blue)
- L wire (for AC/DC and as the feed of the relay outputs) (brown)
- Relay 1 out -- switching to L (black)
- Relay 2 out -- Switching to L (green)
- Purple wire - not connected
- Orange wire - white/brown - Pt
Manual
Wiring Oven side =
Harting style 6+1 connector carrying 3 phase power and relay control signal
- 2 pins for Neutral and Switch (relay)
- 3 pins for the 3 phases
- E pin for Earth
todo
Probably needs a snubber
Risks
Inherent
- Heat runaway (CPU fault, contacts welded)
- Faulty thermocouple causing heat runaway / instability / cracking
- Contact with water/leak
- Material falling onto it / other people working too near / unclear that is hot
Operator driven
- Flammable material near
- Hot handles, etc
- Dust
- Unclear it is on / hot
- Opening while hot
- Bare wire touching
- Looking into it / infrared radiation
- Toppling, bumping, people/things pushed into it
Measures
- Earth leak trip/detector (touching bare metal)
- Heat sensor above oven
- Heat fuse 1 (firing relay), heat fuse 2 (interlock)
- Emergency button
- VK2000 validates heat/cool & stops firing outside control range
- Check ACNode for current & firing
- Overcurrent protection
- No unknown/uncontrolled states on powerup / after powerlock
- Instructions
- Signage (eye, heat, ..)
- Safe location