VK2000-build: verschil tussen versies

Uit MakerSpace Leiden
Ga naar: navigatie, zoeken
(Wiring)
Regel 13: Regel 13:
  
 
On a Harting [https://www.harting.com/sites/default/files/2019-03/98_48_916_0201_User_s_Guide_Termination_Technology_EN.pdf HAN7Da connector].
 
On a Harting [https://www.harting.com/sites/default/files/2019-03/98_48_916_0201_User_s_Guide_Termination_Technology_EN.pdf HAN7Da connector].
 +
 +
= kWh meter =
 +
 +
Dit is een DTS353 -- https://www.rdlmeters.com/product/dts353/ met
 +
[[Bestand:Dts353-manual.pdf|miniatuur|Manual]]
  
 
= Sensor =
 
= Sensor =

Versie van 26 jan 2024 om 17:07


Firing Control VK-200, Ve-Ka Ovenbouw

Firing Control VK-200, Ve-Ka OvenbouwFiring Control VK-200, Ve-Ka OvenbouwFiring Control VK-200, Ve-Ka Ovenbouw

Wiring

  1. N and single 220volt L via switch; black and blue
  2. 2x for the thermocouple - orange cable; white and brown
  3. 2x Normally open relays to switch a load contactor
  4. Earth wire

On a Harting HAN7Da connector.

kWh meter

Dit is een DTS353 -- https://www.rdlmeters.com/product/dts353/ met

Manual

Sensor

  • Nenniger GmbH, Berlin, Hochtemperatur S-Type Thermocouple
  • Special type of cable for this (orange)

Manual

VK-20000 fire control manual

Risks

Inherent

  1. Heat runaway (CPU fault, contacts welded)
  2. Faulty thermocouple causing heat runaway / instability / cracking
  3. Contact with water/leak
  4. Material falling onto it / other people working too near / unclear that is hot

Operator driven

  1. Flammable material near
  2. Hot handles, etc
  3. Dust
  4. Unclear it is on / hot
  5. Opening while hot
  6. Bare wire touching
  7. Looking into it / infrared radiation