Node Lights Out
[OLIMEX PoE] gebaseerde node die kijkt naar de 3 AC netten van het licht.
Inhoud
Wiring and technical data
The 6 screw terminals are Optocoupler detect (2x3) of AC.
All 3 expect AC/230 volt. The RED led on the front is the 'AartLED'.
Code in [[1]]/
Current mac address is 3C:71:BF:10:62:A7 -- wired to the top patch panel, port 23. It is currently connected by a yellow cable to the top switch; port 23 (auto-negotiation, no further settings)
Update September 2019
The AC voltage resistors/optocouplers have been moved out of the low voltage electronics box; and now reside in/behind the two light switches. With just 2 and 4 wires (gnd/E and signal/C of the optocouplers) going to the grey box.
White is the gnd, the colours (brown, orange, green) are the signal wires.
Furthermore GPIO 5 has been wired to a 433 Mhz receiver - for our radio based mains-monitoring.
Building wiring
Note that the building wiring is a bit funny - an earth wire is used as a black-switch phase wire in the leftmost switch.
Opto electronics
Typical log
AC1 to AC3 are the OPTO couplers state; True is off (there is a pull up at work), False is AC voltage detected.
{ "node": "lights", "machine": "lights", "maxMqtt": 768, "id": "a46210bf713c", "ip": "192.168.3.173", "net": "UTP", "mac": "3C:71:BF:10:62:A7", "beat": 0, "approve": 0, "deny": 0, "requests": 0, "cache_hit": 0, "cache_miss": 0, "mqtt_reconnects": 1, "loop_rate": 11137.78, "coreTemp": 72.22222, "heap_free": 223272, "state": "Powered - no lights", "powered_time": 1195, "running_time": 0, "ota": true, "acstate1": true, "acstate2": true, "acstate3": true }