PoE node voor the Ceramic Oven based on a PowerNode White. The QR code points to [this] page.
Use
...
Trouble shooting
See PowerNode White for details; or use the MENU button to see a QR code with logging.
The log file is available on http://ceramics.local/ or http://192.168.6.??/. One can also telnet to this address. Logs are also sent to MQTT and to Syslog at the firewall. Or connect a serial cable; but be sure to use a Galvanic USB isolator.
Configuration
See VK2000-build voor a lot of details.
Board jumpers and settings
Board:
- Rework 1 - half of OPTO resistors replaced by jumpers; 2x68k left in place
- Current coil - 6k8 burden
- Relay 1: Normal 5v Songle relay
- Relay 2: Normal 5v Songle relay
- AC/DC unit soldered in
- Fuse soldered in (100 mAmp, slow)
Jumpers:
- VPOE and VPOE5 both explicit on 'off'
- 5V power via VINT
- Vpower via VINT
- N-jumpers for the Optocouples to get the N from the inputs.
Green Connector
PIN | Description | Use |
---|---|---|
1 | CUR2 | NC -- connector too small |
2 | CUR2 | NC -- connector too small |
3 | CUR1 | NC - connector too small |
4 | CUR1 | NC |
5 | OPTO 2 | NC -- N for voltage sense is wired via jumper to pin 10 at back of board |
6 | OPTO 2 | Voltage sense second relay VK2000 |
7 | OPTO 1 | NC -- N for voltage sense is wired via jumper to pin 10 at back of board |
8 | OPTO 1 | Voltage sense safety relay coil |
9 | L input | L AC in (brown) |
10 | N input | N AC in (blue) |
11 | Relay 1 NO | Start of safety relay |
12 | Relay 1 Common | Start of safety relay |
13 | Relay 2 NO | NC |
14 | Relay 2 NC | Interlock, for stop |
15 | Relay 2 common | Interlock, for stop |
The heating current goes directly through the coil; we're not making use of the connector. Reason for this is that we're not quite sure of the (starting) currents.
Electrics
Basically a SafetyRelay combined ...
Log
...
History