VK2000-build: verschil tussen versies

Uit MakerSpace Leiden
Ga naar: navigatie, zoeken
(Wiring)
Regel 13: Regel 13:
  
 
On a Harting HAN7Da connector.
 
On a Harting HAN7Da connector.
 +
 +
= Sensor =
 +
 +
* Nenniger GmbH, Berlin, Hochtemperatur S-Type Thermocouple
  
 
= Risks =
 
= Risks =

Versie van 22 jan 2024 om 18:13


Firing Control VK-200, Ve-Ka Ovenbouw

Firing Control VK-200, Ve-Ka OvenbouwFiring Control VK-200, Ve-Ka OvenbouwFiring Control VK-200, Ve-Ka Ovenbouw

Wiring

  1. N and single 220volt L via switch; black and blue
  2. 2x for the thermocouple - orange cable; white and brown
  3. 2x Normally open relays to switch a load contactor
  4. Earth wire

On a Harting HAN7Da connector.

Sensor

  • Nenniger GmbH, Berlin, Hochtemperatur S-Type Thermocouple

Risks

Inherent

  1. Heat runaway (CPU fault, contacts welded)
  2. Faulty thermocouple causing heat runaway / instability / cracking
  3. Contact with water/leak
  4. Material falling onto it / other people working too near / unclear that is hot

Operator driven

  1. Flammable material near
  2. Hot handles, etc
  3. Dust
  4. Unclear it is on / hot
  5. Opening while hot
  6. Bare wire touching
  7. Looking into it / infrared radiation