TIG Welder / Lasapparaat

Uit MakerSpace Leiden
Ga naar: navigatie, zoeken
Bestand:Safetysheet-tigwelder.pdf
Safety Sheet tigwelder

TIG 200P AC/DC

TIG Welder

NOTE: the unit can take up to 28 Amps; our circuit is rated at 16 Amps.

Enabling the TIG Welder

The welder is behind an ACNode that also tracks gas-bottle swaps and keeps some statistics on use (it does not yet automatically deduct the gas from your account -- we first need to get some data on actual use/bottle).

To turn on

  1. Swipe tag
  2. Switch the TIG welder on
  3. Open the big valve on top of the bottle
  4. Go wild welding

To turn off

  1. Close the big valve on top of the bottle
  2. Switch the TIG welder off

Do not unplug the unit - the Node stays on to keep track of bottle use / gas loss.

If it beeps / Auto turn-off

If the unit detects gas buildup when disabled; -or- if the unit is powered but not used for over 2 hours - the ACNode will switch the power off. It will then start beeping until someone closes the main valve on top of the bottle (or the bottle runs empty).

To stop it from beeping - close the valve on top of the bottle. And press the 'OK' button on the screen when you are done.

Gas use & payment

The 10Liter bottles at 200 Bar produce around 2000 liters of gas. With a flow rate of 10 Liter/minute; you ought to get some 200 minutes of welding from a single bottle.

Refilling the bottle; and replacing that bottle from time to time gives a cost of 75 euro / 200 minutes, or, rounded up, 50 cent/minute (actual welding/gas-flow) time.

Main Specifications

  • Input Single phase, 240VAC, 24A Max
  • Welding current: up to 185A at 20% DC (5.8 KVA)

Manual

Manual TIG welder

Schematics