Labvoedingen / PSU / Benchpower supply / Voeding: verschil tussen versies

Uit MakerSpace Leiden
Ga naar: navigatie, zoeken
(Usage)
(Usage)
Regel 14: Regel 14:
 
* Use the 'OUTPUT' button to switch between outputs; the little arrow, bottom left, of the display shows which output you are working on.
 
* Use the 'OUTPUT' button to switch between outputs; the little arrow, bottom left, of the display shows which output you are working on.
  
[[Bestand:hp-lcd.jpg|500px]] [[Bestand:hp-keypad.jpg|500px]]
+
[[Bestand:hp-lcd.jpg|500px]]
 +
 
 +
In above image - output '1' is selected; and it currently provides 5 Volt; and there is no current running.
 +
 
 +
[[Bestand:hp-keypad.jpg|500px]]
  
 
* The press the button 'Vset'
 
* The press the button 'Vset'
Regel 20: Regel 24:
 
* Press enter.
 
* Press enter.
 
* Use the output disable/enable button to switch the output on.
 
* Use the output disable/enable button to switch the output on.
 +
 +
You can use 'ISET' and over-current-protection 'OCP' to set a maximum current 'fuse'. OC-RST will reset that fuse. If you do not switch on 'OCP'; then the unit will switch from 'voltage mode' into 'continuous current mode' - and keep delivering the number of A you have set with ISET: and lower the voltage accordingly.
  
 
= specs =
 
= specs =

Versie van 25 mrt 2018 om 22:19

Workbench.jpg

The top shelf of the right hand workbench as two precision power supplies. They are wired to two consoles on the desk itself.

Consoleleft.jpg
Consoleright.jpg

The left hand unit (HP6621A) has 2 output; the right hand unit has 4.

Usage

  • Ensure that nothing is plugged into the console.
  • Power on the unit with the white switch (bottom left)
  • Use the 'OUTPUT' button to switch between outputs; the little arrow, bottom left, of the display shows which output you are working on.

Hp-lcd.jpg

In above image - output '1' is selected; and it currently provides 5 Volt; and there is no current running.

Hp-keypad.jpg
  • The press the button 'Vset'
  • And enter a voltage on the keypad.
  • Press enter.
  • Use the output disable/enable button to switch the output on.

You can use 'ISET' and over-current-protection 'OCP' to set a maximum current 'fuse'. OC-RST will reset that fuse. If you do not switch on 'OCP'; then the unit will switch from 'voltage mode' into 'continuous current mode' - and keep delivering the number of A you have set with ISET: and lower the voltage accordingly.

specs

  1. Left HP6221A
    1. output 1, 0-7 volt, 0-10 Ampere, 0-20 volt, 0-4 Ampere
    2. output 2, 0-7 volt, 0-10 Ampere, 0-20 volt, 0-4 Ampere
  2. Right HP6624A
    1. output 1, 0-7 volt, 0-5 Ampere, 0-20 volt, 0-2 Ampere
    2. output 2, 0-7 volt, 0-5 Ampere, 0-20 volt, 0-2 Ampere
    3. output 3, 0-720volt, 0-2 Ampere, 0-50 volt, 0-0.8 Ampere
    4. output 4 0-720volt, 0-2 Ampere, 0-50 volt, 0-0.8 Ampere